Forensic Engineering Investigation of Electrical and Electronic Causes of an Industrial Equipment Failure
DOI:
https://doi.org/10.51501/jotnafe.v38i2.812Keywords:
Forensic Engineering, Electrical Engineering, Electronic Engineering, Troubleshooting, Investigating, Industrial Equipment, Power Routing, Grounding, National Electrical Code, NEC, Neutral, BondingAbstract
This case involved industrial equipment whose repeated, seemingly random failures resulted in the buyer of that equipment suing the seller. The failures had been isolated to a group of several transistors within electro-mechanical modules within the equipment, but the root cause of those transistors failing had not been determined. The equipment seller had more than 1,000 units in the field with no similar failures. And the electro-mechanical module manufacturer had more than 20,000 units in the field with no similar failures. Electrical contractors hired by the buyer had measured power quality, and reported no faults found in the three-phase power at the equipment terminals. This paper presents circuit analyses of the failing electro-mechanical module, basics of electrostatic discharge damage and protection, and the root cause of these failures — an electrical code-violating extraneous neutral-to-ground bond in a secondary power cabinet.
References
S. Kashyap, “Analyse A Meter,” [Online]. Available: https://analyseameter.com/2020/01/industrial-machines.html. [Accessed 19 May 2021].
X. M. Ren, A. B. Rad, P. T. Chan and W. L. Lo, “Identification and Control of Continuous-Time,” IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, vol. 50, no. 3, pp. 478-487, June 2003.
L. Liptai and J. Cecil, “Forensic Engineering and the Scientific Method,” Journal of the National Academy of Forensic Engineers, vol. XXVI, no. 1, 2009.
eCircuit Center, “Push-Pull Output Stage,” eCircuit Center, 2002. [Online]. Available: http://www.ecircuitcenter.com/Circuits/pushpull/pushpull.htm. [Accessed 3 June 2021].
Fluoron, Incorporated. Staff Writer, “Solutions for Static Buildup on Process Rollers,” Fluoron, The Foll Surface and Release Experts, 25 April 2019. [Online]. Available: https://www.fluoron.com/solution-for-static-buildup-on-process-rollers/. [Accessed 3 June 2021].
SCS, “When Do You Need Ionization?,” SCS (Static Control Systems), 10 January 2019. [Online]. Available: https://scs-static-control-solutions.blog/2019/01/10/when-do-you-need-ionization/. [Accessed 3 June 2021].
National Fire Protection Agency (NFPA), NFPA 70(R): National Electrical Code (R) Handbook, Quincy, MA: NFPA, 2017.
Stack Exchange, “Home Improvement,” StackExchange, 30 March 2020. [Online]. Available: https://diy.stackexchange.com/questions/1706/is-it-ok-to-have-mixed-grounds-and-neutrals-on-bars-in-a-breaker-box. [Accessed 4 June 2021].
M. Holt, “Topic: Why don't you bond the neutral at a sub panel?,” Mike Holt Enterprises, 12 August 2002. [Online]. Available: https://www.mikeholt.com/forum/Forum1/HTML/003455.html. [Accessed 4 June 2021].
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2022 Journal of the National Academy of Forensic Engineers
This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.
All rights © Journal of the National Academy of Forensic Engineers.
Full statement regarding the author's license of copyright to the NAFE is shown on the Copyright section of the Submissions Page.