Review And Analysis Of Defective Septic System Access Resulting In A Fatality

Authors

  • Harold Josephs

DOI:

https://doi.org/10.51501/jotnafe.v17i2.580

Keywords:

Septic system failure

Abstract

A Septic System Access Properly Designed By A Registered Professional Engineer Was Subsequently Modified By Non-Engineers. This Modified Design And Subsequent Construction, Including Inadequate Fastening, Proved Defective And Resulted In The Fatality Of A 2 1/2 Year Old Child. An Fe Investigation And Analysis Was Performed To Determine The Elements Of Causation.

Published

2000-01-01

How to Cite

Josephs, Harold. 2000. “Review And Analysis Of Defective Septic System Access Resulting In A Fatality”. Journal of the National Academy of Forensic Engineers 17 (2). https://doi.org/10.51501/jotnafe.v17i2.580.